Skip to main content
. 2017 Jan 14;10(1):67. doi: 10.3390/ma10010067

Table 2.

Descriptive statistics such as mean with standard deviation (SD), 95% confidence intervals (95% CI), and the minimum/median/maximum. All values for TBS are presented in MPa (N/mm2).

TBS
PEEK Light Curing Unit Mean ± SD 95% CI Min/Median/Max
PEEK/0% LED-LCU chair 10.5 ± 6.7 b 7.0; 13.8 0.0/9.0/ 23.8
lab 6.8 ± 4.7 B,b 4.3; 9.2 0.0/6.4/14.7
HAL-LCU chair 31.2 ± 6.8 a 27.7; 34.6 12.1/31.0/41.2
lab 31.0 ± 4.9 A,B,a 28.4; 33.5 22.3/31.6/38.6
PEEK/20% LED-LCU chair 14.2 ± 6.4 b 10.8; 17.4 0.0/15.6/23.6
lab 13.2 ± 9.6 A,b 8.3; 18.0 0.0/10.9/35.3
HAL-LCU chair 30.9 ± 6.0 a 27.7; 33.9 15.3/32.5/39.1
lab 35.1 ± 10.0 *,A,a 30.0; 40.2 0.0/37.3/43.9
PEEK/>30% LED-LCU chair 13.5 ± 9.2 b 8.8; 17.9 0.0/12.9/34.5
lab 7.8 ± 6.6 *,A,B,b 4.4; 11.2 0.0/8.2/17.3
HAL-LCU chair 29.0 ± 9.8 *,a 24.0; 33.9 4.6/30.7/40.6
lab 26.3 ± 9.8 B,a 21.3; 31.3 2.6/28.3/39.7

LED: Light-emitting diode; HAL: halogen; LCU light curing unit; chair: chairside; lab: labside. * No normal distribution. A,B Significant differences between the PEEK compositions with the same light unit. a,b Significant differences between the light units with the same PEEK composition.