Table 3.

Significant differences on major myocardial motion indices (peak values, 21 pairs of data points) between lateral and septal areas at LV (t-tests). All values are averages over 5 myocardial segments in lateral and septal areas, respectively.

Indices (peak) Lateral (SD) Septal (SD) p values
Drr (cm) 0.80 (0.12) 0.40 (0.12) < 0.001
Dcc (cm) −0.11 (0.6) −0.20 (0.08) < 0.001
Vrr-sys (cm/s) 4.05 (0.99) 2.61 (0.63) < 0.001
Vrr-dia(cm/s) −4.90 (1.07) −2.74 (0.58) < 0.001
Vcc-sys(cm/s) 1.72 (0.41) 2.47 (0.65) 0.006
Vcc-dia(cm/s) −1.61 (0.43) −1.93 (0.51) 0.002
Err 0.45 (0.08) 0.18 (0.07) < 0.001
Ecc −0.20 (0.02) −0.16 (0.02) < 0.001
Ess 0.06 (0.03) 0.04 (0.02) 0.004
SRr-sys (s−1) 2.08 (0.47) 1.03 (0.27) < 0.001
SRr-dia (s−1) −2.32 (1.30) −1.10 (0.51) < 0.001
SRc-sys (s−1) −1.12 (0.29) −0.93 (0.23) < 0.001
SRc-dia (s−1) 0.92 (0.39) 0.75 (0.26) 0.002