Table 4. Pulse Sequence Parameters on MR studies.

Sequence Orientation TR/TE/FA (ms/ms/deg.) AT (min.) Acquisition Matrix Slice thickness/Gap (mm) Fat Suppression
TRUFISP T2-W Coronal 4.30/2.15/80 0.46 512×512 4/0 without
HASTE T2-W Axial 1500/90/170 0.36 320×320 5/0 Without and with (SPAIR)
HASTE T2w Coronal 1500/92/170 0.38 320×320 5/0 without
In-Out phase T1-W Axial 160/2.35/70 0.33 256×192 5/0 without
DWI Axial 7500/91/90 7 192×192 3/0 without
VIBE T1-W Axial 4.80/1.76/12 0.18 320×260 3/0 with (SPAIR)

Note.–W= Weighted, TR = Repetition time, TE = Echo time, FA = Flip angle, AT = Acquisition time, SPAIR = Spectral Adiabatic Inversion Recovery, HASTE = Half-Fourier acquisition single-shot turbo spin-echo, DWI = Diffusion-weighted imaging VIBE = Volumetric interpolated breath hold examination