Table 4.

LRET results using KIIIA-N3X for D signal and KIIIA-Bodipy for SE signal from oocytes under voltage clamp

Clones Voltage τD, ms (n) τSE, m Distance, Å
D1-3GLBT-R(−5) −150mV 2.13 ± 0.03 (6) 1.19 ± 0.02 (5) 43.0 ± 0.5
+20mV 2.42 ± 0.03 (6) 1.29 ± 0.03 (5) 42.3 ± 0.5
D1-3GLBT-R(−6) −150mV 2.34 ± 0.01 (5) 1.11 ± 0.03 (7) 40.8 ± 0.4
+20mV 2.37 ± 0.02 (5) 1.32 ± 0.03 (7) 43.0 ± 0.5
D1-3GLBT-R(−7) −150mV 2.26 ± 0.06 (5) 1.04 ± 0.03 (6) 40.3 ± 0.7
+20mV 2.35 ± 0.01 (5) 1.25 ± 0.02 (6) 42.3 ± 0.4
D4-3GLBT-R(−5) −150mV 2.18 ± 0.04 (5) 0.99 ± 0.01 (5) 40.2 ± 0.4
+20mV 2.30 ± 0.02 (5) 1.19 ± 0.03 (5) 41.9 ± 0.4
D4-3GLBT-R(−6) −150mV 2.21 ± 0.08 (6) 1.01 ± 0.03 (6) 40.3 ± 0.8
+20mV 2.38 ± 0.03 (6) 1.30 ± 0.04 (6) 42.7 ± 0.7
D4-3GLBT-R(−7) −150mV 2.21 ± 0.04 (7) 1.03 ± 0.01 (5) 40.5 ± 0.3
+20mV 2.39 ± 0.05 (7) 1.13 ± 0.01 (5) 40.7 ± 0.4

Values shown are averages ± SE of means. n, number of cells measured.