Skip to main content
. 2017 Mar 14;4:170010. doi: 10.1038/sdata.2017.10

Table 1. Information on scanners, head coils (same across MRI modalities) and MRI individual's datasets counts for each collection included in the primary ABIDE II collections (i.e., datasets collected in a given institution from individuals not included in ABIDE I) and in the longitudinal pilot collections (i.e., data from the same individuals scanned twice: Time 1 data originally released in ABIDE I and Time 2 data released in ABIDE II).

Data collection MRI scanner
Head coil     R-fMRI
High res MRI
DWI *
Manufacturer Model T # channels ASD Contr ASD Contr ASD Contr
Primary Cross Sectional Aggregate
                   
 ABIDEII-BNI_1 Philips Ingenia 3 15 29 29 29 29 29 29
 ABIDEII-EMC_1 GE MR750 3 8 27 27 27 27 0 0
 ABIDEII-ETH_1 Philips Achieva 3 32 13 24 13 24 0 0
 ABIDEII-GU_1 Siemens TriTim 3 12 51 55 51 55 0 0
 ABIDEII-IU_1 Siemens TriTim 3 32 20 20 20 20 0 0
 ABIDEII-IP_1 Philips Achieva 1.5 8 22 33 22 34 21 32
 ABIDEII-KKI_1 Philips Achieva 3 8 56 155 56 155 0 0
 ABIDEII-KUL_3 Philips Achieva Ds 3 32 28 0 28 0 0 0
 ABIDEII-NYU_1 Siemens Allegra 3 8 48 30 48 30 33 24
 ABIDEII-NYU_2 Siemens Allegra 3 8 27 0 27 0 19 0
 ABIDEII-ONRC_2 Siemens Skyra 3 32 24 35 24 35 0 0
 ABIDEII-OHSU_1 Siemens TriTim 3 12 37 56 37 56 0 0
 ABIDEII-SDSU_1 § GE MR750 3 8 33 25 33 25 33 24
 ABIDEII-TCD_1 Philips Achieva 3 8 21 21 21 21 20 20
 ABIDEII-UCD_1 Siemens TriTim 3 32 18 14 18 14 0 0
 ABIDEII-UCLA_1 Siemens TriTim 3 12 16 16 16 16 0 0
 ABIDEII-USM_1 Siemens TriTim 3 12 17 16 17 16 0 0
Total N
487 523 487 557 155 129        

                   
Pilot Longitudinal Aggregate
                   
 UCLA_Long Siemens TriTim 3 12 9 8 14 7 NA NA
 UPSM_Long Siemens Allegra 3 8 14 7 9 8 NA NA
Total N 23 15 23 15        

*For longitudinal collections Diffusion Weighted Imaging (DWI) data were not included ABIDE I, thus are not applicable (NA) here.

For IP one individual ID only has sMRI available.

For KKI_1 an 8-channel head coil was used for n=149 datasets and a 32-channel head coil was used for n=62 datasets—a list of the IDs with the corresponding head coil is provided in the ABIDE II website page for this collection under ‘Additional scan Information’.

§ SDSU also includes field maps corresponding to the R-fMRI and all DTI datasets but two. ASD, Autism Spectrum Disorder; Contr, Controls; GE, General Electrics; High res MRI, High Resolution Magnetic Resonance Imaging; Res, Resolution; R-fMRI, Resting-state functional MRI; T, Tesla; #, number. Also See Supplementary Table 1 for a list of the institutions/investigators.