. 2017 Mar 15;4:11. doi: 10.3389/fcvm.2017.00011

Table 3.

Corrected SNP performance validation in 1-plex comprehensive comprehensive cardiomyopathy (CMP) panel validation after BigDye sequencing.

Metrics TruSight One panel CMP and reflex Hypertrophic cardiomyopathy Dilated cardiomyopathy/left ventricular non-compaction Arrhythmogenic right ventricular cardiomyopathy Marfan syndrome/Loeys–Dietz syndrome Thoracic aortic aneurysms and dissections and reflex
Analytical sensitivity N/Aa 1.00 ± 0.00 1.00 ± 0.00 1.00 ± 0.00 1.00 ± 0.00 N/Aa 1.00 ± 0.00
Analytical specificity N/Aa 0.99 ± 0.00 1.00 ± 0.00 0.99 ± 0.00 1.00 ± 0.00 N/Aa 1.00 ± 0.00
False negative (FN) SNP rate N/Aa 0.00 ± 0.00 0.00 ± 0.00 0.00 ± 0.00 0.00 ± 0.00 N/Aa 0.00 ± 0.00
False positive (FP) SNP rate N/Aa 0.01 ± 0.00 0.00 ± 0.00 0.01 ± 0.00 0.00 ± 0.00 N/Aa 0.00 ± 0.00

aMeasurements not calculated for the designated panels (no BigDye sequencing performed).