Table 2. The sensitivities and specificities from the experiments using DIP, DIP CORE, MHS-PCI and TAP data.
Ratio | 1.0 | 2.0 | 5.0 | 10.0 | |
---|---|---|---|---|---|
DIP | Sensitivity | 96.77 | 92.96 | 85.98 | 78.73 |
Specificity | 73.20 | 83.62 | 91.02 | 95.00 | |
DIP CORE | Sensitivity | 97.89 | 97.19 | 95.40 | 90.50 |
Specificity | 70.23 | 90.77 | 89.76 | 95.21 | |
HMS-PCI | Sensitivity | 94.64 | 96.98 | 95.71 | 93.08 |
Specificity | 62.50 | 72.92 | 91.96 | 93.91 | |
TAP | Sensitivity | 92.70 | 97.23 | 98.30 | 97.66 |
Specificity | 86.67 | 97.43 | 97.70 | 98.60 |