Table VI-1.
Occupational exposure limits for continuous or intermittent noise
Center frequency (Hz) |
OELs by octave-band level (dB) | |||||
---|---|---|---|---|---|---|
480 min | 240 min | 120 min | 60 min | 40 min | 30 min | |
250 | 98 | 102 | 108 | 117 | 120 | 120 |
500 | 92 | 95 | 99 | 105 | 112 | 117 |
1000 | 86 | 88 | 91 | 95 | 99 | 103 |
2000 | 83 | 84 | 85 | 88 | 90 | 92 |
3000 | 82 | 83 | 84 | 86 | 88 | 90 |
4000 | 82 | 83 | 85 | 87 | 89 | 91 |
8000 | 87 | 89 | 92 | 97 | 101 | 105 |