Skip to main content
. 2016 Jun;93(6):498–506. doi: 10.1016/j.contraception.2016.02.024

Table 2.

Cumulative numbers and rates per 100 of selected reasons for IUD removal at 1, 3, 5 and 7 years of use by LNG-IUD and TCu380A IUD in Chinese and non-Chinese centres.

Year
Reason for discontinuation
Chinese centres
Non-Chinese centres
p-value 1
LNG-IUD
TCu380A
LNG-IUD
TCu380A

Events Rate SE Events Rate SE Events Rate SE Events Rate SE
Year 1
 Pregnancies, all 2 0.20 0.14 9 0.89 0.29 0 0.00 0.00 2 0.27 0.19 0.9921
 Expulsions, all 30 0.03 0.01 34 0.03 0.01 23 0.03 0.01 29 0.04 0.01 0.6780
 Bleeding problems 104 10.24 0.95 16 1.56 0.39 56 7.39 0.95 38 5.06 0.80 < 0.0001
 Amenorrhea 46 4.81 0.69 1 0.10 0.10 26 3.64 0.70 0 0.00 0.00 0.9839
 Reduced bleeding 24 2.48 0.50 2 0.20 0.14 14 1.91 0.51 8 1.09 0.38 0.0206
 Increased bleeding 34 3.31 0.56 13 1.27 0.35 16 2.02 0.50 30 4.02 0.72 0.0003
 Pain 10 1.02 0.32 11 1.08 0.32 25 3.45 0.68 19 2.63 0.60 0.5672
 Nondevice-related reasons 3 0.31 0.18 1 0.10 0.10 24 3.28 0.66 21 2.96 0.64 0.3857
Year 3
 Pregnancies, all 6 0.72 0.30 20 2.05 0.45 0 0.00 0.00 4 0.66 0.34 0.9876
 Expulsions, all 52 0.06 0.01 55 0.05 0.01 30 0.04 0.01 40 0.06 0.01 0.2786
 Bleeding problems 253 26.25 1.43 37 3.75 0.61 110 17.42 1.56 59 9.03 1.15 < 0.0001
 Amenorrhea 149 16.88 1.27 1 0.10 0.10 63 10.70 1.31 0 0.00 0.00 0.9777
 Reduced bleeding 61 7.15 0.89 10 1.04 0.33 28 5.03 0.96 10 1.44 0.46 0.0669
 Increased bleeding 43 4.45 0.67 26 2.63 0.51 19 2.62 0.61 49 7.70 1.09 < 0.0001
 Pain 20 2.33 0.52 15 1.51 0.39 39 6.19 0.99 43 7.07 1.06 0.2105
 Nondevice-related reasons 11 1.39 0.42 6 0.63 0.26 86 15.49 1.57 71 12.33 1.40 0.2735
Year 5
 Pregnancies, all 6 0.72 0.30 23 2.39 0.49 1 0.29 0.29 5 0.98 0.47 0.6700
 Expulsions, all 58 0.07 0.01 69 0.07 0.01 34 0.06 0.01 46 0.08 0.01 0.3458
 Bleeding problems 346 37.20 1.60 61 6.51 0.81 133 23.73 1.92 82 15.48 1.69 < 0.0001
 Amenorrhea 217 26.07 1.54 1 0.10 0.10 76 14.48 1.62 0 0.00 0.00 0.9765
 Reduced bleeding 84 10.80 1.14 19 2.09 0.48 34 7.13 1.27 14 2.73 0.78 0.0479
 Increased bleeding 45 4.76 0.70 41 4.42 0.68 23 3.98 0.91 68 13.11 1.59 < 0.0001
 Pain 26 3.35 0.66 20 2.08 0.46 45 8.10 1.24 55 10.63 1.44 0.0746
 Nondevice-related reasons 20 2.98 0.67 15 1.72 0.44 148 32.07 2.28 126 26.29 2.10 0.2896
Year 7
 Pregnancies, all 6 0.72 0.30 27 3.01 0.58 1 0.29 0.29 6 1.44 0.65 0.6232
 Expulsions, all 69 0.09 0.01 80 0.09 0.01 35 0.06 0.01 49 0.09 0.01 0.1934
 Bleeding problems 396 44.41 1.72 87 10.17 1.05 144 28.34 2.27 94 21.60 2.33 < 0.0001
 Amenorrhea 245 31.02 1.70 5 0.70 0.31 78 15.56 1.78 0 0.00 0.00 0.9723
 Reduced bleeding 98 13.74 1.35 27 3.28 0.63 41 10.56 1.78 17 4.64 1.34 0.0753
 Increased bleeding 53 6.57 0.94 55 6.47 0.86 25 5.12 1.21 76 17.31 2.11 < 0.0001
 Pain 28 3.78 0.73 29 3.48 0.65 48 9.98 1.64 67 15.80 2.00 0.1179
 Nondevice-related reasons 27 4.58 0.89 23 2.94 0.61 195 49.07 2.81 161 38.82 2.62 0.4171
1