Skip to main content
. 2017 Apr;19(4):555–569. doi: 10.1016/j.jcyt.2017.01.003

Table I.

Summary of various SPIONs used in this current study, dextran polymers used, polymer-to-iron ratio and the resultant hydrodynamic size and surface charge.

Polymer type Polymer-to-iron salt ratio Hydrodynamic diameter (nm) Surface charge (mV) Intracellular iron content after 4 h labeling (pg) (25 µg/mL labeling) Intracellular iron content after 24 h labeling (pg) (25 µg/mL labeling)
Dextran 4:1 36.0 −3.3 N/A 0.3
CM-dextran 4:1 34.3 −11.6 N/A 0.5
DEAE-dextran 4:1 39.7 +19.6 N/A 2.0
DEAE-dextran 1:1 47.3 +17.7 N/A 2.3
DEAE-dextran 1:4 68.0 +16.8 7.4 9.1
Ferumoxide Unknown 115 −6.7 2.2 4.9
Ferumoxytol Unknown 24.9 −24.2 0.1 0.9

Further information on commercial SPIONs can be found in a review by Li et al.[19].