Skip to main content
. Author manuscript; available in PMC: 2017 Nov 1.
Published in final edited form as: Ophthalmology. 2016 Aug 31;123(11):2309–2317. doi: 10.1016/j.ophtha.2016.07.023

Table 2.

Comparison of the optical coherence tomography angiography (OCT-A)-derived circumpapillary vessel density values between the primary open angle glaucoma subjects with and without a focal lamina cribrosa (LC) defect in global area and in eight 45 degrees sectors.

Eyes with Focal LC Defect (41 eyes, 41 patients) Eyes without Focal LC Defect (41 eyes, 41 patients) P-value

N* OCT-A parameters (%) OCT-A parameters (%)
Global area - 52.9±5.6 (42.4 to 63.1) 56.8±7.7 (35.4 to 71.5) 0.013
Upper temporal 0 57.1±9.9 (32.9 to 72.6) 60.0±9.9 (38.0 to 73.4) 0.107
Upper nasal 0 50.9±6.9 (33.6 to 62.5) 54.1±9.2 (31.9 to 71.4) 0.077
Lower nasal 0 52.7±6.9 (36.4 to 63.3) 52.7±6.9 (32.3 to 66.9) 0.383
Lower temporal 0 54.2±9.3 (34.8 to 70.9) 57.1±9.4 (29.7 to 74.8) 0.155
Superotemporal 19 54.3±8.8 (33.7 to 69.7) 58.8±9.6 (33.8 to 73.1) 0.030
Superonasal 1 53.5±6.7 (40.3 to 65.8) 55.9±7.9 (30.2 to 70.4) 0.133
Inferonasal 1 52.4±9.0 (33.2 to 66.7) 57.6±9.1 (32.3 to 74.1) 0.009
Inferotemporal 33 49.5±10.3 (28.0 to 66.8) 56.8±12.2 (31.8 to 76.0) 0.004

Continuous variables are shown in mean ± standard deviation (range).

*

N = number of eyes with focal LC defects in each of eight 45 degree sectors.

The comparison of the OCT-A parameters was performed between eyes with and without a focal LC defect by using independent samples t-test.