Table 2.
The intra- and interday precision and accuracy of quercetin, luteolin, and apigenin in rat plasma (n = 6).
Compounds | Spiked conc. (μg/ml) | Intraday | Interday | ||||
---|---|---|---|---|---|---|---|
Found conc. (μg/ml) | Precision (RSD%) | Accuracy (%) | Found conc. (μg/ml) | Precision (RSD%) | Accuracy (%) | ||
Quercetin | 0.57 | 0.58 ± 0.04 | 7.31 | 102.38 | 0.58 ± 0.01 | 2.20 | 102.39 |
2.84 | 2.57 ± 0.11 | 4.22 | 90.53 | 2.81 ± 0.25 | 8.81 | 99.05 | |
9.09 | 8.79 ± 0.61 | 6.99 | 96.67 | 8.66 ± 0.11 | 1.31 | 95.31 | |
Luteolin | 0.56 | 0.60 ± 0.02 | 2.79 | 107.74 | 0.61 ± 0.01 | 1.06 | 109.02 |
2.80 | 2.81 ± 0.20 | 7.13 | 100.32 | 2.90 ± 0.08 | 2.89 | 103.68 | |
8.96 | 8.98 ± 0.53 | 5.90 | 100.21 | 8.92 ± 0.05 | 0.54 | 99.61 | |
Apigenin | 0.53 | 0.50 ± 0.04 | 8.32 | 94.59 | 0.49 ± 0.01 | 2.64 | 93.17 |
2.65 | 2.77 ± 0.15 | 5.50 | 104.57 | 2.71 ± 0.05 | 1.88 | 102.36 | |
8.48 | 8.46 ± 0.52 | 6.12 | 99.72 | 8.41 ± 0.04 | 0.47 | 99.23 |