Skip to main content
. 2017 Mar 8;2017:8370584. doi: 10.1155/2017/8370584

Table 2.

The intra- and interday precision and accuracy of quercetin, luteolin, and apigenin in rat plasma (n = 6).

Compounds Spiked conc. (μg/ml)  Intraday  Interday
Found conc. (μg/ml) Precision (RSD%) Accuracy (%) Found conc. (μg/ml) Precision (RSD%) Accuracy (%)
Quercetin 0.57 0.58 ± 0.04 7.31 102.38 0.58 ± 0.01 2.20 102.39
2.84 2.57 ± 0.11 4.22 90.53 2.81 ± 0.25 8.81 99.05
9.09 8.79 ± 0.61 6.99 96.67 8.66 ± 0.11 1.31 95.31
Luteolin 0.56 0.60 ± 0.02 2.79 107.74 0.61 ± 0.01 1.06 109.02
2.80 2.81 ± 0.20 7.13 100.32 2.90 ± 0.08 2.89 103.68
8.96 8.98 ± 0.53 5.90 100.21 8.92 ± 0.05 0.54 99.61
Apigenin 0.53 0.50 ± 0.04 8.32 94.59 0.49 ± 0.01 2.64 93.17
2.65 2.77 ± 0.15 5.50 104.57 2.71 ± 0.05 1.88 102.36
8.48 8.46 ± 0.52 6.12 99.72 8.41 ± 0.04 0.47 99.23