Skip to main content
. 2017 Mar 9;11:634–639. doi: 10.1016/j.dib.2017.03.006
Subject area Environment
More specific subject area Chemical and biological oxygen demand
Type of data Table, figure
How data was acquired DR/5000 UV–vis HACH spectrophotometer
Data format Raw, analyzed
Experimental factors
  • For samples collection from different grey water of Ahvaz, a glass tank was used with a volume of 2–4 l, containing 3 electrode-plate iron and aluminum (Al-Al, Al-Fe, Fe-Fe) was used for Electrocoagulation removal.

  • After collection of wastewater along the car washes, added Sulfuric acid (H2SO4), potassium dichromate (K2Cr2O7), mercury sulfate (HgSO4), silver sulfate (Ag2SO4), potassium hydrogen phthalate (C8H5KO4) and 3-methyl-2-benzothiazoline, then it was stored in a dark place at 4 °C temperature until the metals analysis

  • The effects of contact times, initial pH, electrical potential and voltage were examined.

Experimental features Electrocoagulation between many treatment processes having to be cost-effective for wastewater treatment with pollutant wide range.
Data source location Ahvaz, Iran
Data accessibility Data is with this article.