Skip to main content
. 2017 Mar;360(3):484–495. doi: 10.1124/jpet.116.237438

TABLE 4.

Simulated digoxin CLR and AUC0-∞ parameters in different virtual populations

Each value represents the mean of 100 simulated individuals taken from the virtual population provided with the SimCYP simulator after a single 0.75 mg i.v. dose.

Population Simulated CLR % of healthy CLR Simulated AUC0-∞ % of healthy AUC0-∞
ml/min µg.min/ml
Healthy 131.9 100 3.36 100
Elderly 90.7 69 5.12 152
Moderate renal impairment 65.9 50 5.68 169
Severe renal impairment 43.8 33 7.00 208