Table 2.
Unadjusted means (SD) | Adjusted absolute difference between CEE users and E2 users * | |||||
---|---|---|---|---|---|---|
E2 users (n=93) | CEE users (n=48) | E2 users (n=93) | CEE users (n=48) | P-value | ||
Thrombin Generation | Peak value (nM) | 262.5 (62.1) | 316.0 (85.8) | Reference | +49.8 (21.0 to 78.6) | 0.001 |
ETP (nMxMin) | 1183.5 (255.7) | 1337.0 (361.1) | Reference | +175.0 (54.4 to 295.7) | 0.005 | |
Lag-time (min) | 2.1 (0.34) | 2.0 (0.89) | Reference | −0.01 (−.26 to 0.25) | 0.97 | |
Time to peak (min) | 4.1 (0.7) | 3.8 (1.1) | Reference | −0.2 (−0.5 to 0.2) | 0.27 | |
Factor VII (%) | 136.0 % (38.8) | 135.3 % (36.3) | Reference | −8.7 (−23.0 to 5.6) | 0.23 | |
Antithrombin (%) | 104.5 % (12.7) | 102.8 % (17.5) | Reference | −2.7 (−8.4 to 3.0) | 0.35 | |
Total protein S (%) | 105.9 % (18.2) | 92.3 % (16.6) | Reference | −13.4 (−19.8 to −6.9) | <0.001 |
Adjusted for age, race, BMI, cancer, FVL, use of statins, diabetes, use/dose of progestogen, dose of estrogen
Missing values: Factor VII (n=7), Antithrombin (n=10), Protein S (n=1).
ETP= endogenous thrombin potential