Table 7. Diagnostic performance of the DWI combination analysis by lesion size.
MR size ≤1 cm | MR size >1 cm | p-value† | |
---|---|---|---|
Sensitivity (%) | 80.00 | 95.60 | 0.0340 |
Specificity (%) | 76.00 | 71.43 | >0.9999 |
PPVa (%) | 72.73 | 97.75 | <0.0001 |
NPVb (%) | 82.61 | 55.56 | 0.0745 |
Accuracy (%) | 77.78 | 93.88 | 0.0745 |
AUCc (95% CId) | 0.78 | 0.84 | 0.6231 |
aPPV, positive predictive value
bNPV, negative predictive value
cAUC, area under the curve
dCI, confidence interval.
†p-values were calculated using a Chi-square test and Hanley JA & McNeil BJ's method to determine the difference between two independent AUCs.