Skip to main content
. 2017 Mar 31;83(8):e03295-16. doi: 10.1128/AEM.03295-16

TABLE 1.

Legionella genotype occurrence and environmental parameters measured in a drinking-water system in northern Israela

Sampling pointb MLVA genotypec Prevalence (%) Temp (°C) pH Conductivity (mS/cm)d Chlorine (mg/liter)
A Gt15 86 45.1 ± 5.04 7.57 ± 0.14 1.05 ± 0.04 0.13 ± 0.12
C Gt4 100 19.23 ± 3.05 7.59 ± 0.07 1.02 ± 0.07 0.01 ± 0.003
D Gt4 88 20.85 ± 5.19 7.75 ± 0.21 0.97 ± 0.13 0.15 ± 0.04
E Gt6 100 35.59 ± 6.16 8.36 ± 0.28 0.97 ± 0.06 0.12 ± 0.02
F Gt6 100 23.83 ± 4.25 7.62 ± 0.32 1.03 ± 0.2 0.05 ± 0.01
G Gt6 100 21.58 ± 4.86 7.70 ± 0.29 1.02 ± 0.1 0.41 ± 0.18
a

Data are from reference 19.

b

The selected sampling points in the drinking-water system covered the water route in the sampled zone. Point A was the point closest to where the drinking water entered the sampling area, and points C to G followed the water course.

c

Strains belonging to these three genotypes were examined in the present study. Gt4 and Gt6 strains were classified as serogroup 1, while Gt15 strains were classified as serogroup 3.

d

Millisiemens per centimeter.