Table 7. Mean, standard deviation and p-value for .
Dosimetry System | Moderate | Strong | ||
---|---|---|---|---|
b1 | p | b1 | p | |
DS-U | 3.65 (0.97) | 0.094 | 3.43 (0.50) | <10−4 |
DS-S | 3.77 (2.19) | 0.013 | 3.58 (1.77) | 0.717 |
DS-SU | 3.62 (1.98) | 0.802 | 3.39 (1.66) | <10−4 |
DS-SUP | 3.43 (1.89) | 0.004 | 3.11 (1.4) | <10−4 |
MWDS-2013 | 3.61 (1.48) | 0.813 | 3.33 (0.99) | <10−4 |
Means of b1 estimates are given for moderate and strong model in 5 dosimetry systems. Standard deviations of the estimates and the p-values of the t-test of H0: b1 = 3.6 (true value) are given.