Skip to main content
. 2017 Apr 4;12:64. doi: 10.1186/s13014-017-0784-1

Table 1.

Clinical requirements to target and OARs

Structures Constraints
Mean dose Dose volume
PTV - At least 95% volume of PTV to receive the prescribed dose
OAR Rectum <35 Gy Less than 40% volume to exceed 40 Gy
Bladder <35 Gy Less than 40% volume to exceed 40 Gy
Femur-heads <25 Gy Less than 5% volume to exceed 40 Gy