Skip to main content
. 2017 Mar 2;230(5):639–650. doi: 10.1111/joa.12589

Table 1.

Inter‐day reliability of the shear modulus measured at 80% of maximal ROM

Leg Compartment Muscle layer Transducer location n Mean (SD) (kPa) SEM (kPa) ICC CV (%)
Posterior Superficial GMdis 22 128.5 (27.3) 6.0 0.96 5.3
GMmid 22 106.0 (26.2) 6.0 0.95 6.2
GMpro 22 87.1 (24.7) 7.4 0.92 10.0
GLdis 22 67.1 (24.1) 4.6 0.97 7.8
GLmid 22 65.6 (18.8) 6.2 0.90 11.4
GLpro 22 57.2 (17.4) 4.9 0.93 7.2
SOLdis 22 10.2 (2.7) 1.1 0.85 12.3
SOLpro 22 9.0 (3.0) 1.0 0.91 13.9
Deep FDL 20 14.4 (5.1) 2.4 0.81 14.5
FHL 19 11.1 (3.3) 1.3 0.86 13.8
TP 14 11.0 (4.2) 2.1 0.79 17.8
Lateral Superficial PL 22 15.7 (5.3) 1.5 0.92 13.9
Anterior Superficial TA 21 7.3 (2.3) 0.7 0.92 12.2
EDL 22 8.1 (2.7) 1.0 0.88 13.3

CV, coefficient of variation of the measurement; dis, distal‐leg transducer location; EDL, extensor digitorum longus; FDL, flexor digitorum longus; FHL, flexor hallucis longus; GL, gastrocnemius lateralis; GM, gastrocnemius medialis; ICC, interclass correlation coefficient factor; mid, mid‐leg transducer location; PL, peroneus longus; pro, proximal‐leg transducer location; SEM, standard error of measurement; SOL, soleus; TA, tibial anterior; TP, tibialis posterior.

Data are shown as mean values (± standard deviation).