Skip to main content
. 2017 Mar 2;56(12):3259–3269. doi: 10.1021/acs.iecr.6b04645

Table 3. CO2 Uptake for IER after Exposure to Dry Concentrated CO2, Wet Concentrated CO2, and Post-Processing in Humidified N2.

  q_CO2a adsorption uptake (mol/kgIER)
condition dry wet
120 °C, 72 h, 80%b 1.97 2.10 (2 vol % H2O)
150 °C, 72 h, 80%b 1.69 1.81 (1.8 vol % H2O)
150 °C, 72 h, 100%c 1.66 1.80 (1.8 vol % H2O)
a

q_CO2 = 2.15 for the undegraded IER, measured at 40 °C under 15% CO2/N2.

b

Concentrated CO2 streams were humidified using a water column controlled at 23 °C.

c

Degraded sample was collected, then treated in a flow of N2 at 150 °C containing 0.6% RH for 24 h.