Skip to main content
. 2016 Jul 6;475(5):1349–1355. doi: 10.1007/s11999-016-4966-1

Table 3.

Reasons for revision

Overall Metal Ceramic
Number 28,772 22,675 6097
Revision 643 (2.2) 515 (2.3) 128 (2.1)
Reason Number (%) Number (%) Number (%)
Leg length inequality 8 (1.2) 8 (1.6) 0 (0.0)
Acetabular fracture 2 (0.3) 2 (0.4) 0 (0.0)
Aseptic loosening 71 (11) 61 (12) 10 (8)
Component fracture 10 (1.6) 6 (1.2) 4 (3)
Femoral fracture 25 (4) 20 (4) 5 (4)
Infection 155 (24) 126 (25) 29 (23)
Instability 236 (37) 198 (38) 38 (30)
Polyethylene insert wear 26 (4) 16 (3) 10 (8)
Osteolysis 5 (0.8) 2 (0.4) 3 (2)
Other 32 (5) 29 (6) 3 (2)
Periprosthetic fracture 83 (13) 68 (13) 15 (12)
Wound dehiscence 2 (0.3) 2 (0.4) 0 (0.0)
Wound drainage 22 (3) 18 (4) 4 (3)
Hematoma/seroma 37 (6) 29 (6) 8 (6)
Cup malposition 3 (0.5) 3 (0.6) 0 (0.0)
Metallosis 2 (0.3) 1 (0.2) 1 (0.8)

There may be multiple reasons for revision.