Skip to main content
. 2017 Apr 3;12:2645–2656. doi: 10.2147/IJN.S132670

Table 3.

Clinical performance of mRT-LAMP-CIRN compared with real-time RT-PCR for detecting influenza A/H1N1pdm09, A/H3 and influenza B

mRT-LAMP-CIRN Real-time RT-PCR
Performance characteristics
Positive Negative Sensitivity, % Specificity, %
A/H1N1pdm09
 Positive 34 0 97.1 100
 Negative 1 59
A/H3
 Positive 14 0 100 100
 Negative 0 80
Influenza B
 Positive 9 0 100 100
 Negative 0 85
Combined A/H1N1pdm09, A/H3 and FluB
 Positive 57 0 98.3 100
 Negative 1 36