Effect of cardiac shock wave therapy on the parameters of exercise capacity

Study (year) Study type Number of patients who underwent CSWT Value before CSWT Value after CSWT Measurement unit
Caspari G.H. et al. (1999) [19] Single arm 9 58±18 111±18 Wt
Gutersohn A. et al. (2005) [52] Single arm 14 70±15.3 100±16.8 Wt
Lyadov K. et al. (2006) [55] Single arm 13 11.9±2.2 14.1±2.8 VO2 ml/kg/min
Fukumoto Y. et al. (2006) [54] Single arm 9 3.9±1.9 5±1.7 Met
Schmid J.P. et al. (2006) [75] Randomized, Placebo controlled 7 98±27 115±15 Wt
Naber C. et al. (2008) [58]a Single arm 24 66.6±33.3 95.8±24.5 Wt
Faber L. et al. (2010) [60] Single arm 16 80±45 90±39 Wt
Vainer J. et al. (2010) [61] Single arm 22 7.8±4 8.5±3 Minutes
Kikuchi Y. Et al. (2010) [31] Placebo controlled 8 44.7±16.2 50.5±16.2 Wt
Vainer J. et al. (2012) [63] Single arm 50 8.2±3.2 9.6±3.8 Minutes
Kazmi W.H. et al. (2012) [71] Controlled 43 12.2±7.8 20.1±15.7 Minutes
Yang P. et al. (2012) [79] Randomized, Placebo controlled 25 339.44±83.3 427.9±63.3 Meters
Wang Y. et al. (2012) [24]b Randomized, controlled 31 344.3±106.4 434.3±99.7 Meters
Schmid J.P. et al. (2013) [78] Randomized, Placebo controlled 11 91.2±29.1 94.1±35.2 Wt
Prinz C. et al. (2013) [66] Single arm 43 78±53 90±46 Wt
Cassar A. et al. (2014) [27] Single arm 15 319.8±157.2 422.1±183.3 Seconds
Zhao L. et al. (2015) [74]b Randomized, controlled 32 343.9±85.0 489.4±72.2 Seconds
Prasad M. et al. (2015) [68] Single arm 111 252.1±51.6c 313.5±164.3 Seconds
457.0±146.8d 606.0±126.4
Kaller M. et al. (2015) [49] Single arm 16 93±44 101±41 Wt
Cai HY. et al. (2015) [30] Single arm 26 360.7±116.8 434.2±86.3 Meters
Nirala S. et al. (2016) [73] Controlled 41 336.7±120.5 445.8±172.4 Meters
Vainer J. et al. (2016) [70] Single arm 33 7.4±2.8 8.8±3.6 Minutes

All valuables presented as mean ± SD, avaluable presented as mean ± SE, SE calculated into SD using standard formulas; bgroup with standard CSWT protocol, cBruce protocol, dmodified Bruce protocol