Table 1.
Causes of failure of 59 refrigerators assessed in Uganda.
Cause of failure | Manufacturer, model (count), and device type* |
|||||
---|---|---|---|---|---|---|
Dometic RCW 42 EGa (n = 44) | Dulas Solar VC-65 (n = 11) | Vestfrost MF 314c (n = 1) | Sibir V 170 GEb (n = 2) | Vestfrost MK 304d (n = 1) | Total (n = 59) | |
Absorption | Solar compression | Freezer, AC** compression | Absorption | AC** compression | ||
Cooling unit fault | 44 | 44 | ||||
Refrigerant leak | 5 | 1 | 6 | |||
Control unit fault | 2 | 1 | 3 | |||
Thermostat fault | 2 | 2 | ||||
Stolen solar panel | 2 | 2 | ||||
Blocked gas tube | 2 | 2 |
a, refrigerator; b, refrigerator and freezer; c, freezer; d, ice-lined refrigerator.