TABLE I.
Reverberation time (T30) and standard deviations measured in the three rooms per octave band. The babble noise spectrum (dBA) was measured per octave band using the HATS.
Parameter (s.d.) | Room | 125 Hz | 250 Hz | 500 Hz | 1000 Hz | 2000 Hz | 4000 Hz | 8000 Hz |
---|---|---|---|---|---|---|---|---|
T30 (s) | Anechoic | 0.05 | 0.04 | 0.04 | 0.04 | 0.04 | 0.04 | 0.04 |
(0.005) | (0.007) | (0.006) | (0.005) | (0.005) | (0.005) | (0.007) | ||
T30 (s) | Semi-reverberant | 1.01 | 0.92 | 0.78 | 0.79 | 0.79 | 0.73 | 0.55 |
(0.02) | (0.06) | (0.02) | (0.01) | (0.02) | (0.02) | (0.02) | ||
T30 (s) | Reverberant | 1.26 | 1.82 | 2.23 | 2.52 | 2.33 | 1.66 | 1.01 |
(0.06) | (0.03) | (0.06) | (0.04) | (0.11) | (0.05) | (0.02) | ||
Babble noise spectrum (dBA) | 34.8 | 46.6 | 58.1 | 59.0 | 48.3 | 40.1 | 27.1 |