. 2005 Jan;43(1):468–471. doi: 10.1128/JCM.43.1.468-471.2005

TABLE 2.

Performance of the CSFV real-time RT-PCR assay after evaluation of VI-negative CSFV real-time RT-PCR-positive samples by RT-nested PCR

Test indexa % 95% Confidence interval
Sensitivity 100 (65/65) 100-100
Specificity 98.9 (380/384) 97.9-99.9
Positive predictive value 94.3 (65/69) 88.6-99.7
Negative predictive value 100 (380/380) 100-100
False-negative rate 0.00 (0/65) 0.0-0.0
False-positive rate 5.7 (4/69) 1.8-14.9
Overall accuracy 99.1 (445/449) 98.9-99.9
a

Sensitivity, number of positive samples over number of true-positive samples; specificity, number of negative samples over number of true-negative samples; positive predictive value, number of samples that were positive and had CSFV; negative predictive value, number of samples that were negative and did not have CSFV; false-negative rate, number of negative samples confirmed positive over true-positive samples; false-positive rate, number of positive samples confirmed negative over true-positive samples; overall accuracy, total of true-positive and true-negative samples over the total number of samples.