Maximum absolute values of Ieph from time t = 0.02 to 1 ms as a function of σe as computed by the EMI method.

σe (μS/μm) Iephmax (nA/μm2) σe·Iephmax (nAμS/μm3)
0.1 0.616 0.0616
0.3 0.208 0.0623
0.6 0.104 0.0625
1.5 0.042 0.0626
3.0 0.021 0.0627

We observe that σe·Iephmax is close to constant for the different values of σe. The parameters used in the computations are given in Table 2.