Table 3.
Maximum absolute values of Ieph from time t = 0.02 to 1 ms as a function of σe as computed by the EMI method.
σe (μS/μm) | (nA/μm2) | (nAμS/μm3) |
---|---|---|
0.1 | 0.616 | 0.0616 |
0.3 | 0.208 | 0.0623 |
0.6 | 0.104 | 0.0625 |
1.5 | 0.042 | 0.0626 |
3.0 | 0.021 | 0.0627 |
We observe that is close to constant for the different values of σe. The parameters used in the computations are given in Table 2.