. 2017 Apr 18;9:205–212. doi: 10.2147/IJWH.S132391

Table 2.

PPIUDCS

Author (year) Study design and IUD Population Comparison Event rates
Comments
Expulsion Medical removal Pregnancy
Bhutta et ala,7 (2011) MLCu 375 insertion at CS vs 6 W and no IUD PPIUDCS 50
IIUDCS 50
Control 50
Post-placental vs 6W vs no IUD Same in all groups
No numbers given
Same in all groups
No numbers given
0 6 M follow-up. No difference in puerperal bleeding in all groups
Elsedeeka,10 (2012) Nova T 380 vs Mirena vs control at CS Nova T 380 63
Mirena 60
Control 63
Nova T vs Mirena on puerperal bleeding Nova T 7.9%
Mirena 0%
0
0
0
0
Nonrandom. 6 W follow-up. Mirena group bled significantly less
López-Farfan et al9 (2012) Mirena vs TCu380A at CS. RCT Mirena 198
TCu380A 198
Mirena vs TCu380A Mirena 4.5%
TCu380A 4.5%
2%
3.5%
0
0
12 M percentage rates
Gueye et al19 (2013) Open evaluation of TCu380A at CS.
Uncontrolled
PPIUDCS 56 0 2.2% 2.3% 0 6 M percentage follow-up rates
Singal et al21 (2014) Open evaluation of TCu380A at CS PPIUDCS 300 0 5.23% 7% 0.6% 12 M percentage rates
Tjahjannto et al20 (2014) Open evaluation of TCu380A sutured to fundus at CS “hang-up” technique PPIUDCS 108 0 0 0.95% 0.9% Pearl index and percentage rates at 12 M
Whitaker et al17 (2014) Mirena at CS vs at 4–8 W post-CS. RCT PPIUDCS 20
IIUDCS 22
Mirena at CS vs later insertion at post-partum visit At CS 20%
At 4–8 W 0%
Not stated 0
0
12 M follow-up. Percentage rates
Braniff et al13 (2015) Mirena at CS vs 6 W post-CS. RCT PPIUDCS 23
IIUDCS 19
Mirena at CS vs later insertion at post-partum visit At CS 0%
At 6 W 0%
Not stated 0
0
6 M follow-up. Percentage rates. High satisfaction in both groups
Lester et al12 (2015) TCu380A at CS vs 6 W post-CS. RCT PPIUDCS 34
IIUDCS 18
TCu380A at CS vs later insertion at post-partum visit At CS 3%
At 6 W 5%
At CS 3%
At 6 W 5%
0
0
6 M follow-up. Percentage rates
Levi et al15 (2015) Comparison of Mirena and TCu380A at CS vs 6 W+ post-CS. RCT as to timing of insertion Mirena PPIUDCS 40
TCu380A PPIUDCS 15
Mirena IIUDCS 30
TCu380A IIUDCS 4
Mirena or TCu380A at CS vs later insertion at post-partum visit At CS (combined results) 8% At 6 W (combined results) 2% At CS (combined results) 15% At 6 W (combined results) 4% 0
0
6 M follow-up. Percentage rates. Participants selected type of IUD
Elsedeek11 (2015) Mirena vs Nova T 380 at CS. Open study Mirena 80
Nova T 63
Mirena vs Nova T at patient request Mirena 0%
Nova T 6.3%
Mirena 3.8%
Nova T 7.9%
Nova T 6.3%
Mirena 0%
60 M follow-up. Percentage rates, misalignment at 6 W more common with Mirena
Ragab et al14 (2015) Nova T 380 vs TCu380A vs MLCu 375 at CS. RCT Nova T 380 40
TCu380A 40
MLCu 375 40
Three-way comparison of different copper IUDs inserted at CS Nova T 13%
TCu380 15%
MLCu 5.6%
Not stated Nova T 3%
TCu380 3%
MLCu 0%
12 M follow-up. Percentage rates. Expulsion rate of MLCu 375 was significantly lower than the other two Strings lengthened with vicaryl

Notes: Results from December 2012 to June 2015 search, unless otherwise stated.

a

Included from earlier search because of widened inclusion criteria. Mirena (Bayer AG, Levekusen, Germany); Nova T 380 (Bayer AG); MLCu 375 (Multiload Copper 375; Multilan SA, Fribourg, Switzerland); TCu380A, Teva Pharmaceutical Industries Ltd., Petach Tikva, Israel).

Abbreviations: PPIUDCS, post-placental IUD at CS; IIUDCS, interval insertion of IUD after CS; CS, cesarean section; IUD, intrauterine contraceptive device; RCT, randomized controlled trial; vs, versus; W, weeks; M, months.