Skip to main content
. 2017 Apr 18;9:205–212. doi: 10.2147/IJWH.S132391

Table 3.

Missing strings after PPIUDCS

Study IUD Number Strings observed (%) Interval after insertion Comments
Zhang H et al23 GyneFix PP 200 86 6 W The device is attached to the fundus under direct vision
Nelson et al36 TCu380A 7 100 6 W Modified extended strings guided through cervix into vagina
Levi et al34 TCu380A 32 28 6 W Normal strings placed in the cervix
Lester et al12 TCu380A 27 44 6 W
Bhutta et al7 MLCu 375 50 92 and 92 6 W and 6 M Long thread of MLCu 375 pushed through the cervix
Singal et al21 TCu380A 300 61 and 84 6 W and 12 M More strings seen at 12 M follow-up
Braniff et al13 Mirena 23 31.6 6 W Strings not directed through the cervix
Levi et al15 Mirena 21 67 6 M
TCu380A 10 40 6 M
Ragab et al14 Nova T 380 40 100 6 W and 60 W Strings lengthened with vicryl and placed through cervix
MLCu 375 40 100 into the vagina
TCu380A 40 100

Notes: Mirena (Bayer AG, Levekusen, Germany); Nova T 380 (Bayer AG); MLCu 375 (Multiload Copper375; Multilan SA, Fribourg, Switzerland); GyneFix PP (Contrel Europe NV, Ghent, Belgium).

Abbreviations: PPIUDCS, post-placental IUD at CS; IIUDCS, interval insertion of IUD after CS; CS, cesarean section; IUD, intrauterine contraceptive device; W, weeks; M, months.