Skip to main content
. 2017 Feb 3;312(4):H721–H727. doi: 10.1152/ajpheart.00835.2016

Table 1.

Hemodynamic data at the end of the protocol

Ctrl ECMO ECMO-TH
Hemoglobin, g/dl 8.9 ± 0.3 7.9 ± 0.5 8.2 ± 0 0.6
Glucose, mg/dl 96 ± 11 103 ± 11 87 ± 15
HR, beats/min 102 ± 9 115 ± 9 116 ± 7
LVSP, mmHg 75 ± 5 62 ± 2* 61 ± 1*
LVEDP, mmHg 8 ± 1 4 ± 1* 4 ± 1*
RVSP, mmHg 25 ± 2 16 ± 1* 16 ± 1*
RVEDP, mmHg 7 ± 1 5 ± 1 5 ± 2
AoF, l/min 1.17 ± 0.05 1.20 ± 0.06 1.13 ± 0.04

Values are means ± SE. HR, heart rate; LVSP, left ventricular systolic blood pressure; LVEDP, left ventricular end-diastolic pressure; RVSP, right ventricular systolic blood pressure; RVEDP, right ventricular end-diastolic pressure; AoF, aortic flow. AoF is equivalent to total systemic output from both ECMO pump and LV ejection.

*

P < 0.05 vs. Ctrl.