Skip to main content
. 2017 Feb 3;312(4):H768–H780. doi: 10.1152/ajpheart.00728.2016

Table 1.

Echocardiographic analysis of Med1cKO mice

Genotype n Sex HR, Beats/min EDV, μl ESV, μl Mass, mg SV, μl CO, μl/m EF, %
Postnatal
    Med1fl/fl 11 M 672 ± 22 13.8 ± 0.94 2.6 ± 0.26 42.2 ± 4.3 11.3 ± 0.7 7437 ± 657 82.0 ± 0.01
    Med1cKO 8 M 449 ± 24* 47.8 ± 14.3* 32.4 ± 13.4* 66.2 ± 11.4* 15.3 ± 1.7** 6639 ± 513 48.2 ± 0.08*
    Med1fl/fl 6 F 668 ± 17 11.3 ± 0.07 2.3 ± 0.19 43.5 ± 4.1 9.0 ± 0.7 5434 ± 638 79.0 ± 0.02
    Med1cKO 7 F 481 ± 29** 48.5 ± 15.8** 32.6 ± 12.2** 69.4 ± 6.6** 16.0 ± 1.7** 7823 ± 1202 44.8 ± 0.08**
Adult
    Med1fl/fl 6 M 629 ± 47 32.0 ± 5.9 9.3 ± 2.9 76.2 ± 3.3 22.6 ± 3.4 13673 ± 1579 72 ± 0.03
    Med1cKO-MCM 9 M 640 ± 46 86.5 ± 9.9* 67.6 ± 10.4* 102.9 ± 6.9* 18.9 ± 2.8 12439 ± 2144 26 ± 0.06*
    Med1fl/fl 4 F 645 ± 47 41.0 ± 10.5 11.0 ± 3.2 88.5 ± 11.1 30.0 ± 7.4 9233 ± 3984 74 ± 0.02
    Med1cKO-MCM 5 F 513 ± 78 106.9 ± 12.6** 79.6 ± 14.7** 122.4 ± 11.3** 27.4 ± 2.8 13879 ± 2326 28 ± 0.06**

Values are means ± SE. Echocardiographic analysis of 3-wk-old Med1fl/fl and Med1cKO male (M) and female (F) mice and Med1fl/fl and Med1cKO-MCM male and female mice 21–28 days after the start of tamoxifen treatment. HR, heart rate; EDV, end diastolic volume; ESV, end systolic volume; SV, stroke volume; CO, cardiac output; EF, ejection fraction.

*

P < 0.05 compared with Med1fl/fl M mice;

**

P < 0.05 compared with Med1fl/fl F mice.