MRI Acquisition Parameters

Parameters T1-Weighted T2-Weighted Diffusion-Weighted R2*
Pulse sequence Rapid acquisition rapid echo with variable repetition time (RARE-VTR) Multislice multiecho (MSME) Echo planar Multigradient echo (MGE)
Respiratory gating No No No Yes
Repetition time (ms) 193.44, 478.4, 878.44, 1555.502, 5000 2500 3000 1500
Echo time (ms) 6.16 13 TEs from 7.4 to 98.02 16.81 First TE 3.5 ms with 4-ms echo spacing
Field of view (mm) 30 × 30 30 × 30 30 × 30 30 × 30
Matrix 256 × 256 256 × 256 128 × 128 256 × 256
Number of signal averages 1 1 4 1
b values (s/m2) Not applicable Not applicable 100, 250, 500, 750, 1000 Not applicable
Spatial resolution (mm/voxel) 0.117 × 0.117 0.117 × 0.117 0.234 × 0.234 0.117 × 0.117
Slice thickness (mm) 1 1 1 1