Skip to main content
. 2017 Apr-Jun;20(2):207–211. doi: 10.4103/aca.ACA_229_16

Table 3.

Comparative efficacy of the four tests

Parameters Value as per

MMT (%) TMD test (%) SMD test (%) TMHT (%)
True positive 17 7 6 24
False positive 59 5 8 9
True negative 254 (73) 308 (89) 305 (88) 304 (88)
False negative 15 25 26 8
Sensitivity 53 22 19 75
Specificity 81 98 97 97
Positive predictive value 22 58 43 73
Negative predictive value 94 92 92 97
Accuracy 79 91 90 95

True positive: A difficult laryngoscopy that had been predicted to be difficult. False positive: An easy laryngoscopy that had been predicted to be difficult. True negative: An easy laryngoscopy that had been predicted to be easy. False negative: A difficult laryngoscopy that had been predicted to be easy. MMT: Modified Mallampati test, TMD: Thyromental distance, SMD: Sternomental distance, TMHT: Thyromental height test