Data-collection parameters
Instrument: ESRF BM29
Wavelength (Å) 0.99
q-range (Å-1) 0.0032 – 0.49
Sample-to-detector distance 2.864 m
Exposure time (sec) 1 per frame
Concentration range n.a.
Temperature (K) 293
Detector Pilatus 1M (Dectris)
Flux (photons/s) 1 × 1012
Beam size (µm2) 700 × 700
Structural parameters for D5323-785, SEC
I0 (cm-1) [from Guinier] 0.0237
Rg (Å) [from Guinier] 48
qminRg – qmaxRg used for Guinier 0.77 - 1.24
Dmax (Å) [from p(r) ] 145
q-range used for p(r) (Å-1) 0.02 - 0.17
Porod volume Vp3) [from Scatter] (570 ± 5) × 103
Molecular mass Mr (kDa) [from Vp] 345
Calculated monomeric Mr from sequence (kDa) 321
Structural parameters for D5323-785, IEC
I0 (cm-1) [from Guinier] 0.386
Rg (Å) [from Guinier] 46.5 ± 0.1
qminRg – qmaxRg used for Guinier 0.44 - 1.29
Dmax (Å) [from p(r) ] 120
q-range used for p(r) (Å-1) 0.03 - 0.18
Porod volume Vp3) [from Scatter] (577 ± 5) × 103
Molecular mass Mr (kDa) [from Vp] 339
Calculated hexameric Mr from sequence (kDa) 321