Organs at risk dose-volume constraints and goal for the planning target volume (PTV) used for adjuvant prostate IMRT planning

Organ Dose (Gy) Volume (%)
Bladder 50 65
65 50
70 35
Rectum 40 60
50 50
60 35
70 20
Femoral Heads 30 50
50 10
Small Bowell 15 120 cc
45 195 cc
PTV Dpre a 98

a Prescription Dose