Values of the parameters adopted in the two convergence tests.

Parameter Description Value
α Conduction velocity scaling 2.0 cm ms−1 mS−1/2
β Surface-to-volume ratio 1000 cm−1
σel Longitudinal extra-cellular conductivity 3 mS cm−1
σet Transverse extra-cellular conductivity 1.2 mS cm−1
σec Cross extra-cellular conductivity 1.2 mS cm−1
σil Longitudinal intra-cellular conductivity 3 mS cm−1
σit Transverse intra-cellular conductivity 0.3 mS cm−1
σic Cross intra-cellular conductivity 0.3 mS cm−1
Vref Resting potential −80 mV
Vdep Depolarization potential 30 mV
εdep Depolarization time-scale 1 ms
εrep Repolarization time-scale 100 ms
APd Action potential duration 200 ms