Skip to main content
. 2016 Mar 4;7:10854. doi: 10.1038/ncomms10854

Figure 4. Magnetization reversal versus current density and magnetic field.

Figure 4

Measurements show the normalized change in anomalous Hall resistance RAHE with current density J and applied magnetic field BIP (a) parallel and (b) perpendicular to the EB direction. The small difference in horizontal axes is caused by a resistance difference between the two directions of the Hall cross. Evaluation of the LLG equation, including Joule heating and local variations in the EB direction and magnitude, produces comparable phase diagrams for both the (c) parallel and (d) perpendicular configurations when computing the switch probability Pswitch.