Skip to main content
. 2017 Apr 26;9(4):355–362. doi: 10.4330/wjc.v9.i4.355

Table 3.

Procedural characteristics

Procedural characteristics Overall (n = 64) Success (n = 41) Failure (n = 23) P value
Planned initial attempt 45 (70.3%) 29 (70.7%) 16 (69.6%) 1
Retrograde approach 9 (14.1%) 6 (14.6%) 3 (13.0%) 1
Contralateral injection 36 (56.3%) 22 (53.6%) 14 (60.9%) 0.76
Parallell wire 16 (25%) 10 (24.3%) 6 (26.1%) 1
Intravascular ultrasound 8 (12.5%) 8 (19.5%) 0 (0%) 0.042
Rotablator 5 (7.8%) 5 (12.2%) 0 (0%) 0.15
Change of operator 39 (60.9%) 27 (65.9%) 12 (52.2%) 0.41
Experienced operator 36 (56.3%) 27 (65.9%) 9 (39.1%) 0.065
Change in guide catheter 11 (17.2%) 7 (17.1%) 4 (17.4%) 1
Change of wire 38 (59.4%) 23 (56.1%) 15 (65.2%) 0.65
Microcatheter use 46 (71.9%) 28 (68.3%) 18 (78.3%) 0.57
Procedure time 127.8 ± 44.3 129.1 ± 51.3 125.3 ± 32.8 0.71
Fluroscopy time 45.44 ± 21 43.3 ± 21.5 49.2 ± 20.0 0.27
Contrast (mL) 337.5 ± 127.5 355.5 ± 127.2 305.4 ± 124.3 0.13