Skip to main content
. 2012 Aug 6;134(8):0810021–08100211. doi: 10.1115/1.4007092

Table 1.

vWf response to shear stress

Shear stress range (Pa) Exposure time (s) Consequences Reference
3.7 12 Enhanced cleavage of vWf multimer [22]
6.5 ∼0.2 (repetitive) Reduction in high molecular weight multimers in patients with aortic stenosis [23]
10 Stress required to unfold the functional domain [25]