Skip to main content
. 2017 Apr 4;17(4):764. doi: 10.3390/s17040764

Table 1.

Summary of the performances of the HVPA with and without the power MOSFET linearizer under various DC bias voltages.

HVPA without Power MOSFET Linearizer HVPA with the Power MOSFET Linearizer (DC Bias Voltages)
1 V 3 V 6 V 9 V 10 V
Gain deviation at 70 MHz (dB) −2.95 −2.25 −2.16 −2.01 −1.85 −1.80
Gain deviation at 80 MHz (dB) −3.00 −1.37 −1.31 −1.11 −1.01 −0.96
IP1dB at 70 MHz (dBm) 22.03 23.43 23.56 23.88 23.97 24.17
IP1dB at 80 MHz (dBm) 22.13 24.43 24.85 25.89 26.16 26.19