Skip to main content
. 2017 Apr 10;17(4):820. doi: 10.3390/s17040820

Table 4.

Output voltage of the transformer under different currents (D = 5 mm, f = 50 Hz).

Uc/mV Up/mV I/A Uc/mV Up/mV I/A
60 264 1.99 632 2880 22.01
121 568 4.01 680 3120 23.97
180 860 6.02 744 3360 26.01
226 1120 7.98 808 3600 27.99
292 1380 10.03 848 3840 30.02
352 1600 12.01 920 4160 32.02
396 1880 13.99 968 4320 34.02
464 2160 16.03 1020 4560 36.01
516 2360 17.97 1080 4720 37.99
580 2640 20.01 1140 5040 40.02