. 2017 Apr;7(2):129–150. doi: 10.21037/cdt.2017.03.22

Table 4. Dynamic CT perfusion imaging in animal studies.

Author N. CT technology Reference standard Analysis Dose (mSv)
Bamberg et al., 2012 (70) 7 pigs DS 2° g Microsphere MBF Quantitative MBF 10.6
Schwarz et al., 2013 (71) 6 pigs DS 2° g Microsphere MBF Quantitative MBF + attenuation values (HU) 11.3+0.88
Rossi et al., 2013 (72) 7 pigs DS 2° g CBF and FFR Quantitative MBF 17.1
Bamberg et al., 2014 (73) 12 pigs DS 2° g Histopathology microsphere MBF Quantitative MBF, MBV, Ktrans NA

All the studies but one (72) used adenosine at a dose of 0.14 mg/kg/min. Rossi et al. used adenosine at a dose of 0.50 mg/kg/min (72). CBF, coronary blood flow; CT, computed tomography; DSCT, dual-source CT scanner; FFR, fractional flow reserve; HU, Hounsfield unit; Ktrans, permeability constant; mSv, millisievert; MBF, myocardial blood flow; MBV, myocardial blood volume; N., animals’ number; NA, non assessable.