Uniformity of the illumination field in the low-cost SMLM by using different diffusers. (a,c) Spatial distribution of illumination intensity generated by the flat-top diffuser. (b) The corresponding intensity profile across the blue dotted line in a. The size of the illumination field with a relative intensity larger than 90% is 48 µm. (c) Spatial distribution of illumination intensity generated by the Gaussian diffuser (#47-994, Edmund Optics). (d) The corresponding intensity profile across the blue dotted line in (c). The size of the illumination field with a relative intensity larger than 90% is 27 µm. Note that, the inset shown in the left bottom corner in (a,b) is the original illumination pattern without diffuser.