Skip to main content
. 2017 Jan 18;88(3):248–254. doi: 10.1080/17453674.2016.1278345

Table 6.

Cox regression results for reverse hybrid brand combinations compared to cemented THAs with follow-up of more than 5 years, and with adjustment for age, sex, and diagnosis

Prosthesis cup/stem Total n Revised n RR 95% CI p-value At 8 years n At 10 years n
Cemented THA 155,845 2,825 1 90,886 52,447
Elite/Corail 1,818 11 0.4 0.2–0.7 0.02 426 168
Titan/Corail 499 7 0.6 0.3–1.3 0.2 239 107
Kronos/Corail 369 2 0.3 0.1–1.4 0.1 74 30
Reflection all-poly/Corail 628 25 2.0 1.4–3.1 < 0.001 217 88
Contemporary/ABG II HA 311 2 0.5 0.1–1.8 0.3 51