. 2017 Apr 3;27:22. doi: 10.1038/s41533-017-0016-z

Table 1.

Frequency of overall error with devices (quantitative and qualitative estimates)

Device Cross-sectional studies RCTs
Number of studies Pooled estimate [95% CI] (I-squared)* Range of error frequency Number of studies Pooled estimate [95% CI] (I-squared)* Range of error frequency
MDI 19 86.8% [79.4–91.95] (98.5%) 45.7–100.0% 2 89.5% [75.7–95.9] (60.0%) 85.1–94.2%
MDI with spacer 3 52.0% [24.3–78.6] (87.3%) 31.6–78.0% 0 N/A N/A
BA-MDI (Autohaler®) 2 57.7% [52.9–62.5] (84.9%) 54.9–59.9% 0 N/A N/A
Turbuhaler® 4 55.5% [24.5–82.7] (93.6%) 22.0–88.7% 3 73.6% [55.6–86.1] (92.1%) 54.0–82.2%
Diskus® 1 N/A 49.0% 3 62.4% [51.9–72.0] (61.6%) 50.0–68.3%
Aerolizer® 2 75.1% [31.0–95.3] (97.2%) 54.0–89.1% 0 N/A N/A
Handihaler® 0 N/A N/A 1 N/A 66.7%

N/A Not applicable

* I-squared statistic indicates the percentage of variance that is attributable to between-study heterogeneity. The higher the percentage, the greater the heterogeneity. Not applicable as number of studies was ≤1