Skip to main content
. 2017 Apr 24;27:29. doi: 10.1038/s41533-017-0031-0

Table 3.

Logistic regression model variables showing significant predictive likelihood for correct inhaler technique maintenance

Predictor Coding B SE Deviance df p value Odds ratio 95% CI for odds ratio
Lower Upper
Inhaler technique at VISIT 1 0 = Correct technique (n = 56) 1.965 .455 17.431 1 .000 7.131 3.104 18.922
1 = Incorrect technique (n = 182)
Regimen Score Score range 1–7 .275 .127 4.498 1 .031 1.317 1.027 1.701
Device type 0 = DPI (n = 167) .791 .355 5.344 1 .026 2.205 1.116 4.554
1 = pMDI (n = 71)a

Outcome variable coding for inhaler technique maintenance: 0 = maintained correct inhaler technique, 1 = did not maintain correct inhaler technique.

a MDI and MDI with a spacer groups were combined under pMDI to achieve sufficient group size for logistic regression analysis