Skip to main content
. 2017 Apr 6;56(17):5042–5054. doi: 10.1021/acs.iecr.7b00433

Table 2. Experimental Conditions for Adsorption, Desorption, and Cyclic Steady-State Runs.

run  (g/s)  (mL/s) uf (m/s) Re kLS (m3/(m2 s)) Dporee (m2/s) Dsf (m2/s) Cin (ppm) Tinlet (°C)
1a 2 1.52 0.002 13.5 0.91 × 10–4 1.4 × 10–9 4.5 × 10–12 1550 20.8
2a 3 2.27 0.003 20.2 1.09 × 10–4 1.4 × 10–9 4.8 × 10–12 1680 21.4
3a 4 3.03 0.004 27.0 1.24 × 10–4 1.4 × 10–9 4.9 × 10–12 1640 21.8
4a 5 3.79 0.005 33.7 1.38 × 10–4 1.4 × 10–9 7.1 × 10–12 1700 21.5
5a 7 5.30 0.007 47.2 1.62 × 10–4 1.4 × 10–9 2.2 × 10–12 1750 22.0
6b 0.55 196.43 0.260 138 0.1129 2.0 × 10–5 5.0 × 10–7 200 100
7b 0.65 232.14 0.307 164 0.1233 2.0 × 10–5 5.0 × 10–7 200 100
8b 0.75 267.86 0.355 214 0.1331 2.0 × 10–5 5.0 × 10–7 200 100
9b 0.85 303.57 0.402 239 0.1424 2.0 × 10–5 5.0 × 10–7 200 100
10b 0.95 339.29 0.449 265 0.1512 2.0 × 10–5 5.0 × 10–7 200 100
11c 0.95 339.29 0.449 265 0.1512 2.0 × 10–5 5.0 × 10–7 200 100
12d 3–0.95 2.27–339.29 0.003–0.449 20.2–265 1.24 × 10–4–0.1512 1.4 × 10–9–2.0 × 10–5 4.8 × 10–12–5.0 × 10–7 1700–200 22–100
a

Adsorption.

b

Desorption.

c

Desorption with external heating.

d

Cyclic steady state with external heating.

e

Data taken from Basmadjian et al.2

f