Table 4.
Parameters and goodness of fit for mathematical models of AWB responses in odr-3 mutants.
| Conditions | AWB, odr-3(n2150) | AWB, odr-3(n1605) |
|---|---|---|
| Durations of up/down phase | down 90 s | down 90 s |
| Number of samples (frames) used for calculation of BIC | N = 180 (t = −60 ~ 120 s) |
N = 180 (t = −60 ~ 120 s) |
|
|
k = 89.1 [μM−1·s] BIC = 25.1 |
k = 77.3 [μM−1·s] BIC = −39.2 |
|
|
k = 2.08 [μM−1] τ → ∞ BIC = −477.7 |
k = 1.77 [μM−1] τ → ∞ BIC = −578.5 |
|
|
k = 8.71 [μM−1] τ = 25.2 [s] ∆t = 67 [s] BIC = −645.6 |
k = 7.73 [μM−1] τ = 23.5 [s] ∆t = 66 [s] BIC = −779.9 |