Skip to main content
. 2017 May 23;7:2310. doi: 10.1038/s41598-017-01991-y

Table 2.

Diagnostic accuracy of ultrasound measurements of BPD for prenatal assessment of microcephaly.

Cut-off −3 SD −4 SD −5 SD
Number of cohorts 218, 19 218, 19 218, 19
Number of comparisons 51 51 51
Diagnostic odds ratio (DOR) 1.6 (0.056–46.1), I2 = 0% 4.7 (0.86–25.5), I2 = 0% 4.7 (0.66–33.9), I2 = 0%
AUC 0.888 0.77 0.66
Sensitivity 0.94 (0.67–0.99) 0.85 (0.46–0.98) 0.59 (0.30–0.83)
Specificity 0.16 (0.06–0.37) 0.46 (0.14–0.81) 0.80 (0.21–0.99)
Positive likelihood ratio 1.1 (0.82–1.5) 1.6 (0.70–4.5) 3.0 (0.59–46.0)
Negative likelihood ratio 0.38 (0.047–2.5) 0.33 (0.045–1.9) 0.51 (0.21–2.6)
PPV (general pregnancy) 0.00032 0.00045 0.00084
NPV (general pregnancy) 0.99989 0.99991 0.99985
PPV (ZIKV-infected pregnancy) 0.0106 0.0109 0.0275
NPV (ZIKV-infected pregnancy) 0.9964 0.9969 0.995

Parentheses indicate 95% CI. Pre-test probabilities, i.e. incidence of microcephaly among general pregnancies and ZIKV-infected pregnancies were estimated as 0.0285% and 0.95%, respectively.